Choose a 40G QSFP+ transceiver by matching the link distance, installed fiber type, connector, and equipment compatibility. SR4 is generally suited to short-reach multimode links, LR4 to 10 km single-mode links, ER4 to longer single-mode links around 40 km, and PSM4 to parallel single-mode links up to about 500 m. These are typical reach specifications; the actual supported distance depends on the module specification, fiber plant, and network equipment. Before ordering, confirm the exact part number and optical interface against both ends of the link.
Click here to get more.
This guide is for network operators, data center teams, system integrators, and procurement professionals sourcing 40G QSFP+ optical transceivers. It is intended for projects where the link distance or fiber infrastructure makes it necessary to compare SR4, LR4, ER4, and PSM4 rather than select a module by data rate alone. We focus on practical selection considerations that affect deployment and sourcing. If a link is part of a migration or mixed-vendor network, compatibility checks are especially important.
A 40G QSFP+ transceiver is a pluggable optical module that connects a compatible network port to fiber-optic cabling. QSFP+ identifies the form factor, while the optical variant describes how the signal is transmitted and what fiber and reach the module is designed to use. The four options in this guide all support a nominal 40 Gb/s link, but they use different optical architectures and cabling. Their connectors and reach are not interchangeable by default.
| Variant | Optical approach | Typical maximum reach | Typical fiber and interface | Common fit |
|---|---|---|---|---|
| SR4 | Four parallel lanes at 850 nm | 100 m on OM3; 150 m on OM4 | Multimode fiber; MPO/MTP | Short data center links |
| LR4 | Four wavelengths around 1310 nm | 10 km | Duplex single-mode fiber; typically LC | Campus or longer building links |
| ER4 | Four wavelengths around 1310 nm | 40 km | Duplex single-mode fiber; typically LC | Extended-reach single-mode links |
| PSM4 | Four parallel lanes around 1310 nm | 500 m | Single-mode fiber; MPO/MTP | Short-to-medium single-mode links |
Reach values shown are common application specifications, not a guarantee for every product or installed cable plant. Check the specific module datasheet and the optical link budget before deployment. LR4 and ER4 use wavelength multiplexing to carry the lanes over a duplex fiber pair, while SR4 and PSM4 use parallel optical paths through a multi-fiber interface. That difference drives cabling, patch-panel, and migration choices.
SR4 is a common choice when a short link already has suitable multimode fiber. It transmits across four lanes at 850 nm and typically uses an MPO/MTP connector. A common reach reference is 100 m over OM3 or 150 m over OM4, subject to the transceiver and cabling specifications. Where supported by the equipment, an MPO-to-LC breakout harness can also be used for 4 × 10G connections.
LR4 is designed for single-mode links that need more reach than a typical multimode installation. It combines four optical wavelengths, commonly around 1271, 1291, 1311, and 1331 nm, onto a duplex fiber pair. A typical specified reach is 10 km, with a duplex LC interface commonly used. Select LR4 when the installed route and equipment requirements fit its reach and optical budget.
ER4 extends the reach of a 40G single-mode connection, with products commonly specified for distances up to 40 km. Like LR4, it generally uses wavelength multiplexing over a duplex fiber pair and a duplex LC interface. Its longer reach can be useful for campus, metro, or other extended links, but distance alone is not enough to confirm suitability. Validate attenuation, connector losses, dispersion considerations where applicable, and the exact transmitter and receiver specifications.
With competitive price and timely delivery, OPTEKCOM sincerely hope to be your supplier and partner.
PSM4 carries four parallel optical lanes over single-mode fiber, generally using an MPO/MTP interface. A common application specification is up to 500 m, making it a potential option for medium-distance links where parallel single-mode cabling is available. Unlike LR4 and ER4, it does not combine the four lanes onto a duplex pair. Account for the required fiber count, polarity, and end-to-end patching before choosing it.
A module that matches the fiber type may still be unsuitable if the host device does not support its coding or operating characteristics. Share the switch or router manufacturer, model, port details, and required coding with your supplier before ordering. If both ends use different platforms, confirm compatibility at each end rather than assuming that identical optics are required. We recommend validating the exact SKU and application before finalizing a bill of materials.
Purchase cost depends on the selected optical variant, compatibility requirements, order quantity, and any requested customization or testing documentation. MOQ and lead time can also vary with product configuration, stock position, and order volume, so they should be confirmed for the specific quotation rather than assumed from the interface name. Consider total deployment cost as well as module price, including the required trunks, breakout harnesses, patch panels, and installation work. For planned rollouts, request the same specification across the required quantity and agree on any sample or qualification process before volume purchasing.
One frequent mistake is selecting by “40G QSFP+” alone, without confirming whether the link needs multimode or single-mode fiber. Another is overlooking the physical interface: an MPO/MTP module and a duplex LC module require different cabling arrangements. Buyers can also misread maximum reach as a guarantee for an existing plant, even when patching or fiber losses exceed the applicable budget. Finally, breakout capability should be confirmed with the switch and configuration, not inferred from the transceiver label.
At OPTEKCOM, we supply fiber-optic equipment, including optical transceivers and interconnect cables, for B2B network projects. To help us recommend a suitable 40G QSFP+ option, provide your required reach, fiber type, connector, host-device models, quantity, and whether you need breakout. We can use those project details to clarify the appropriate product specification and cabling requirements. Availability, compatibility, MOQ, and lead time should be confirmed for the requested configuration.
For short multimode links, start with SR4; for a 10 km duplex single-mode link, consider LR4; for an extended single-mode route approaching 40 km, evaluate ER4; and for a parallel single-mode link up to about 500 m, consider PSM4. The right choice depends on the installed fiber, reach, connector, optical budget, and host compatibility—not just the 40G data rate. Before placing an order, document these requirements and validate the exact module and cable combination at both ends. Contact OPTEKCOM with your equipment and link details to discuss a suitable 40G QSFP+ transceiver and interconnect configuration.
For more 40g qsfp+information, please contact us. We will provide professional answers.